Некоторые типы масел для поршневых компрессоров, работающих на (H)CFC хладонах или NH3 (по данным фирмы Bitzer)
| Поставщик | Марка масла | Тип масла | Вязкость (40 С), сСт | Область применения | | Хладоны | NH3 | | BITZER | B 5.2 | MO/AB | 39 | HML | | | SHELL & DEA OIL | Clavus G 68 | MO | 65 | | HM | | ADDINOL | XK30 | AB | 30 | HML | | | XKS46 | AB | 46 | HML | | | XKS68 | AB | 64 | HML | | | AGIP | TER32 | MO | 30 | HM (L) | | | TER46 | MO | 44 | HM | | | TER60 | MO | 59 | HM | HM | | ARAL | Alur EE32 | MO | 32 | HM (L) | | | Alur EE46 | MO | 46 | HM | | | Alur EE68 | MO | 68 | HM | | | BP | Energol LPTF32 | MO | 32 | HM (L) | | | Energol LPTF46 | MO | 46 | HM | HM | BURMAN / CASTROL | Icematic 266 | MO | 30 | HM (L) | | | Icematic 299 | MO | 57 | HM | | | Icematic 2284 | AB | 64 | HML | | | ESSO | Zerice S46 | AB | 48 | HML | | | Zerice S68 | AB | 64 | HML | | | Zerice R46 | MO/AB | 50 | HM (L) | | | Zerice R68 | MO | 68 | HM | | | FUCHS EUROPE | Reniso SP32 | AB | 32 | HML | | | Reniso SP46 | AB | 47 | HML | | | Reniso SP68 | AB | 68 | HML | | | Reniso Triton MS32 | MO/AB | 30 | HM (L) | | | Reniso Triton MS46 | MO/AB | 43 | HM | | | Reniso Triton MS68 | MO/AB | 63 | HM | | | Reniso KM32 | MO | 32 | HM (L) | | | Reniso KS46 | MO | 47 | HM | | | Reniso KC68 | MO | 68 | HM | HM | | MOBIL | Artic C heavy | MO | 44 | HM | | | Artic Oil 300 | MO | 60 | HM | HM | | Artic SHC 426 | AB | 65 | HML | | | PETRO-CANADA | Reflo 68A | MO (HT) | 58 | | HM | | PETROSYNTESE | Zerol 150 | AB | 30 | HML | | | Zerol 300 | AB | 53 | HML | | | SHELL & DEA OIL | Clavus SD2212 | MO/AB | 39 | HML | | | Clavus G32 | MO | 30 | HM (L) | | | Clavus G46 | MO | 44 | HM (L) | | | Clavus G68 | MO | 65 | HM | HM | | Clavus 68 | MO | 65 | | HM | | SUN OIL | Suniso 3GS | MO | 30 | HM (L) | | | Suniso HT25 | MO | 43 | HM (L) | | | Suniso 4GS | MO | 57 | HM | H (M) | TEXACO / CALTEX | Refrig. Oil Low Temp.32 | MO/AB | 30 | HM (L) | | | Refrig. Oil Low Temp.46 | MO/AB | 43 | HM | | | Refrig. Oil Low Temp.68 | MO/AB | 63 | HM | | | Capella Oil WF 32 | MO | 30 | HM (L) | | | Capella Oil WF 46 | MO | 46 | HM | | | Capella Oil WF 68 | MO | 68 | HM | HM | | TOTAL | Lunaria 32 | MO | 32 | HM | | | Lunaria 46 | MO | 46 | HM | | | Lunaria FR 32 | MO | 30 | HM (L) | | | Lunaria FR 46 | MO | 43 | HM (L) | | | Lunaria FR 68 | MO | 68 | HM (L) | | | Friga 2 | MO | 58 | HM | HM | | Lunaria SK 55 | AB | 50 | HML | | | WINTERSHALL | Wiolan KFL | MO | 32 | HM (L) | | | Wiolan KFM | MO | 46 | HM | | | Wiolan KFO | MO | 68 | HM | HM | |